Looking for reliable LED lighting products or a customized solution for your project? ROKEE Lighting provides product selection, photometric design, OEM/ODM services and technical support for sports venues, industrial facilities, roads and hazardous areas worldwide. Tell us about your project, and our lighting specialists will help you find the right solution.

Get in Touch
Tel: +86-186 6537 8687
Address: ROKEE Lighting Industrial Park, No. 7 Hongyun Road, Longbeiling, Tangxia, Dongguan, Guangdong, China
Visit ROKEE Lighting
ROKEE Lighting reception desk and company sign
G7 150W LED gas station canopy light with emergency function
G7 150W LED gas station canopy light with emergency function
G7 IP65 LED gas station canopy light recessed mounting design
G7 150W LED gas station canopy light with emergency functionG7 IP65 LED gas station canopy light recessed mounting design

Product Parameters

  • Model: GS-01-G7
  • Power Range: 80W–150W
  • System Efficacy: Up to 140 lm/W
  • Beam Options: 30°, 60°, 90° and 150°
  • Input Voltage: AC100–277V
  • Controls: ON/OFF, 0–10V and ZigBee
  • Emergency Function: Optional
  • Protection: IP65 and IK09
  • Mounting: Recessed canopy installation
  • Lifespan: Over 50,000 hours
  • Warranty: 5 years
Inquiry

Product Details

The ROKEE G7 LED gas station canopy light delivers efficient, uniform illumination for petrol stations, service areas and covered commercial facilities. Available in 80W, 100W, 120W and 150W models, it reaches up to 140 lm/W and includes an optional emergency-lighting configuration for projects that require backup illumination.

Key Features of the G7 LED Gas Station Canopy Light

The recessed structure creates a clean canopy appearance and supports straightforward installation in new construction or retrofit projects. A durable optical assembly, high-transmission materials and an impact-resistant housing are designed for busy forecourts. The available emergency function can maintain essential visibility when normal power is interrupted; emergency wattage, runtime and battery requirements should be confirmed for each project.

Optical Performance and Controls

Beam angles of 30°, 60°, 90° and 150° allow the distribution to be matched to canopy height, fixture spacing and target illuminance. Narrower beams support longer projection, while wider beams improve coverage beneath lower canopies. Control options include ON/OFF, 0–10V dimming and ZigBee, enabling simple switching, scheduled reduction or integration with site controls.

LED gas station canopy light with optional emergency function

Durability and Service Life

IP65 sealing protects the luminaire from dust and water jets, and IK09 impact resistance supports use in demanding commercial environments. The AC100–277V input covers common international power systems. CCT choices of 3000K, 4000K, 5000K and 5700K help match the visual appearance and brand requirements of the fuel station. Rated life exceeds 50,000 hours and the fixture is covered by a five-year warranty.

Applications

Suitable for petrol stations, service stations, EV charging areas, toll stations, covered parking entrances, convenience-store canopies and other commercial forecourts.

Technical Specifications

Model GS-01-G7
Power 80W / 100W / 120W / 150W
System Efficacy Up to 140 lm/W
Input Voltage AC100–277V, 50/60Hz
Beam Angles 30° / 60° / 90° / 150°
CCT 3000K / 4000K / 5000K / 5700K
CRI Over 80
Controls ON/OFF / 0–10V / ZigBee
Protection IP65 / IK09
Emergency Function Optional
Warranty 5 years

Canopy Lighting Design Considerations

Canopy lighting should be selected from mounting height, bay dimensions, fixture spacing and required illuminance rather than wattage alone. Uniformity is important because strong bright spots and dark zones can reduce visual comfort for drivers and staff. The chosen beam should place useful light on fueling positions, circulation paths and payment areas while limiting glare toward surrounding roads and nearby properties.

For retrofit projects, confirm the ceiling opening, available mounting depth, structural support and cable entry before ordering. Emergency, dimming and wireless-control functions should be defined in the project specification. Final emergency output and duration must comply with local regulations and be verified on the approved submittal.

Installation and Project Support

Installation should be completed by qualified personnel using properly rated cables, connectors and mounting hardware. Confirm supply voltage, grounding, control wiring and ingress protection before energizing the luminaire. Keep seals clean, tighten fasteners to the specified torque and test dimming or emergency functions during commissioning.

ROKEE can support photometric simulation, fixture spacing, product selection and project quotations. Send canopy drawings, mounting heights, target lux levels, electrical information and site photographs so the recommended configuration can be checked before installation.

Explore our LED gas station canopy lights, review industrial lighting projects, or contact ROKEE for a canopy lighting layout and quotation.

Back To Top